|
Variable
area flow meters
RA/FA
60/65
 |
- Classical
variable area flow meter
- Minimal
pressure losses
- Borosilicate
glass
- Steel
fittings
- Extensive
connection variants
- Optionally:
- Light
switches for a process control
Technical Data
|
RA/FA
77
 |
-
Variable area flow meter for aggressive
- measuring
media
- Borosilicate
glass
- PVC
fittings
- Extensive
connection variants
- Optionally:
- Light
switches for a process control
Technical
Data
|
RA/FA
87
 |
-
Variable area flow meter
- Borosilicate
glass
- Stainless
steel fittings
- Extensive
connection variants
- Optionally:
- Light
switches for a process control
Technical
Data
|
SGA
 |
-
Variable area flow meter
- Borosilicate
glass
- Pressure
balanced measuring glass
- Armoured
fittings
- Direct
indication without need of electricity
Technical
Data
|
SGM
 |
- All
- metal variable area flow meter
- Four
versions:
Stainless steel,stainless steel/PTFE-lining, PP,PVC
- Extensive
connection variants
- Optionally:
- Explosion
proof version
- Optionally:
- Light
switches for a process control
- Measure
value transducer 4 -20mA /
0 -10V
- Measure
value transducer with totalisator and display
Technical
Data
|
Short
- tube VA flow meters
SGK
 |
-
Variable area flow meter
- Borosilicate
glass
-
Versions:
PVC, aluminium anodised, stainless steel,PP,PVDF
- Optionally:
- Dosing
value
- Extensive
connection variants
- Optionally:
- Light
switches for a process control
Technical
Data
|
SKM
 |
-
Piston - type flow meter
- Borosilicate
glass
-
Versions:
Brass, stainless steel,PP,PVDF
- Optionally:
- Light
switches for a process control
- Installation
independent from the direction of the flow
- Rather
independent from viscosity
Technical
Data
|
SMK
 |
-
All metal variable area flow meter
- High
pressure and temperature resistance
-
Optionally:
- Dosing
valve
- Extensive
connnection variants
- Optionally:
- Explosive
proof version
- Limit
switches for process control
- Measure
value transducer 4 - 20mA
Technical
Data
|
Flap
- type flow meters
KDA
 |
-
Flow indicator
- Readable
through a glass disk
-
Versions:
- Grey
cast iron, stainless steel
- Extensive
connection variants
Technical
Data
|
KLA
 |
- Flap-type
flow meter
-
Flow indicator
on glass disk or with a pointer
- Extremely
relaible device
-
Versions:
- Grey
cast iron, stainless steel, rubber - coated grey cast iron
- Optionally
- Limit
switches for a process control
Technical
Data
|
KFS
 |
-
Flow meter with spring - loaded flap
-
To be assembled between flanges
-
Versions:
- Steel,
stainless steel, PVC, PP, PVDF
- Installation
independant from the direction of the flow
- Optionally
- Limit
switches for a process control
- Measured
value transducer 4 - 20mA / 0 - 10 V
- Measured
value transducer with totalisator and display
Technical
Data
|
Differential
pressure and bypass flow meters
DDW/DDM
 |
-
Differential pressure manostat DDW
-
Screw connection
- Installation
independant of the flow direction
- Limit
switches for a process control
- Differential
pressure flow meter DDM
- Screw
connection or to be assembled between flanges
- Installation
independant of the flow direction
- Indication
of standard flow units
Technical
Data - DDW
Technical Data - DDM
|
SMB
 |
- Sprinkler
orifice plate
-
VdS approval no: G 4990049
- To
be assembled between flanges
- Installation
independant of the flow direction
- Approved
nominal widths:
DN 80, DN 100, DN 150, DN 200
Technical
Data
|
DST
 |
- Bypass
flow meter
- To
be assembled between flanges
- Versions
- Steel,
stainless steel, PVC, PP, PVDF
- Installation
independant of the flow direction
- Optionally:
- Limit
switches for a process control
Technical
Data
|
|