Welcome to our website

Famsystem Technology offers a wide range of technologies and manufactures in the premises situated in Germiston. We have extensive experience on all of our products well over 30 years.

Famsystem Technology has representation in KZN and Western Cape and supplies plant and equipment to the whole of South Africa as well as exporting to Africa and beyond.

Image is not available

Our Recent Works

Browse through Famsystems latest projects portfolio.

Image is not available

Containerised Sewage Plant

Image is not available

+

previous arrow
next arrow
PlayPause
Slider

Sewage Plants

Sewage Plants

The FAMSYSTEM Sewage Systems will treat effluent and sewage producing water in accordance with the Department of Water Affairs Specification of 5 April 1962, R553, General Standard…

Containerised Sewage Plants

Containerised Sewage Plants

Example of our Sewage Container: 12 metres and 6 metres in series With a HDPE chlorine disinfection tank This was installed in a caravan park to handle 40 Kl/day with a BOD of 350 MG/L   View SENET – 2017...

Famsystems RHC Plants

Famsystems RHC Plants

After the success of the Famsystem FMP process, the need for a larger system became apparent. This design had to conform to the same basics as used in the FM process including; Possibility for extension in time using a modular process Capability of handling both Gernal and Special standard effluents with the various recycles required for this process. Offer the same cost advantage Based on the modular process, the Famsystem RHC plant was developed. The sytem has proven to be less expensive than other designs and only batch type systems can compete on a price basis. However as the Famsystem RHC design is based on a continuous process, effluent quality is of continuous excellent quality. The design is a rectangular reinforced concrete structure with baffles in fibreglass. The standard layout offers a dual stream system, so that at any stage in the future maintenance can be done without stopping the flow of sewage. The aeration system in this process uses fine bubble aeration system which is well suited for the rectangular layout and for these higher flows, also reduces the power requirement of the plant. The Famsystem RHC process offer the following advantages of the system are obvious, and it offers: Easier civil work in that only a simple reinforced concrete construction is required. Design can be adapted to suit both special inlet conditions and effluent requirements Special peak flows can be handled easily It incorporates all the aspects of a successful activated sludge design including all recycle systems that may be required to achieve the required results. The Famsystem RHC plant can be supplied as an open plant or as shown in the enclosed photograph can be covered with a fibreglass roof. The plant, as for all other designs, does not produce an odour as it makes use of submerged fine bubble aeration with excess air being made available. This is in stark contrast with mechanical aerators or paddle type units, which create significant odours making the latter not suitable to be installed close to housing or offices. Using multiple reactors in one plant, the Famsystem RHC system can be applied to plants of just over 2Ml/day Operational results both locally and in...

Famsystem FMP

Famsystem FMP

MEDIUM SYSTEM: TYPE FAMSYSTEM FMP The various sections of an activated sludge process are clearly visible in the construction of the Famsystem FMP unit as each zone is contained in a separate tank. An anaerobic or interceptor tank: this tank is used for the initial digestion of the incoming sewage as well as the possible storage of activated sludge, if sludge can not be dried on site and has to be removed. The aeration tanks (or tank) are flat-bottomed tanks with a special aeration ring positioned in the bottom of the tank. Air is introduced and by means of the special aeration system, intimate contact is established between the air and the solid matter. Aeration efficiency is not time dependant and remains at these high levels even after many years of operation. A number of designs are available to ensure that aeration is optimised in each plant. The third section of the plant consists of a clarifier tank where solids are settled and a clear overflow liquid is produced. Although more expensive to manufacture, only conical tanks are used for this application so that all sludge collected in the tank can be recycled. No solids will build up in the bottom of the tank which would become anaerobic and cause foaming in the settler, generating a dirty effluent. The final contact tank is a chlorine contact tank, which finally treats the liquor to produce an effluent in accordance with the General Limits in terms of the South African Water Act Standard suitable for discharge into rivers or for use as irrigation. Clarification and disinfection tanks are designed for the typical peak values which are experienced in smaller plants This conservative approach ensures that the Famsystem sewage plants offer good results under all operating conditions. The basic system described above, has been extended to include a number of recycles and anoxic zones to improve the nitrogen removal of the plants, as without these recycles lower nitrate levels will not be achieved. The Famsystem FMP process is designed for individual applications to ensure that all aspects of the application are fully taken into consideration. As standard equipment is used, costs can be kept to a minimum....